57 Closed loop stepper motor 2

The unique tube clamp linkage mechanism, with the opening process of the upper pressure block, the tube clamp automatically lifts, the user can easily install the tube. As the upper pressure block is closed, the tube clamp is automatically reset to fix the tube. At the same time, the trigger lever assist mechanism assists the user in pressing the upper pressure block. Users can choose single or dual-channel pump heads. You can also choose a pump head with a fixed or adjustable tube pressure gap according to your requirements. 

Characteristic

Industry application

Support anorectal therapeutic instrument

Support biofermentation cylinder

Tubing Installation Procedure

    1. Turn the knob anticlockwise 180º, open the upper block.
    2.  Rubbing wheel adjustment.
    3.  Put the tube between rollers and upper block, tighten up the tubing lightly.
    4.  Turn the knob clockwise 180º, put the upper block back to original position, fasten the tube.

Pump Head and Flow Rate

Pump Head Tubing IDxWall thickness (mm) ml/r Flow Rate (ml/min) (0.1-150rpm) Tubing Max.Pressure (Mpa) Intermittent Tubing Max.Pressure (Mpa) Continuous Weight (kg)
Single Channel HF-EasyPump I/III
13#
0.8x1.6
0.053
0.0053~32
0.27
0.17
0.6
Single Channel HF-EasyPump I/III
14#
1.6x1.6
0.27
0.027~162
0.27
0.17
0.6
Single Channel HF-EasyPump I/III
19#
2.4x1.6
0.55
0.055~330
0.27
0.17
0.6
Single Channel HF-EasyPump I/III
16#
3.1x1.6
0.933
0.093~560
0.27
0.17
0.6
Single Channel HF-EasyPump I/III
25#
4.8x1.6
1.967
0.197~1180
0.24
0.14
0.6
Single Channel HF-EasyPump I/III
17#
6.4x1.6
3.333
0.333~2000
0.14
0.10
0.6
Single Channel HF-EasyPump I/III
18#
7.9x1.6
4.3
0.430~2580
0.10
0.07
0.6
Single Channel HF-EasyPump II/IV
15#
4.8x12.4
1.8
0.180~1080
0.27
0.17
0.6
Single Channel HF-EasyPump II/IV
24#
6.4x2.4
2.733
0.273~1640
0.27
0.17
0.6
Single Channel HF-EasyPump II/IV
35#
7.9x2.4
3.833
0.383~2300
0.24
0.14
0.6
Single Channel HF-EasyPump II/IV
36#
9.6x2.4
5.167
0.517~3100
0.24
0.14
0.6
Dual Channel HF-EasyPump V/VI
13#
0.8x1.6
0.053
0.0053~32
0.27
0.17
0.6
Dual Channel HF-EasyPump V/VI
14#
1.6x1.6
0.27
0.027~162
0.27
0.17
0.6
Dual Channel HF-EasyPump V/VI
19#
2.4x1.6
0.55
0.055~330
0.27
0.17
0.6
Dual Channel HF-EasyPump V/VI
16#
3.1x1.6
0.933
0.093~560
0.27
0.17
0.6
Dual Channel HF-EasyPump V/VI
25#
4.8x1.6
1.967
0.197~1180
0.24
0.14
0.6

Technical Specification

Speed range 0.1-600rpm
Flow rate range
0.0053-3100ml/min
Speed control
External input pulse frequency speed control
Subdivision settings
4-speed DIP switch setting (default 16 subdivisions)
Current setting
Adaptive current
Motor type
57 Closed-loop stepper motor
Power supply
DC18~50V (recommend 36V)
Logic input voltage
5V
Working environment
0-40ºC, 80%RH

Product Dimension Drawing (mm)